{"id":2384,"date":"2025-01-21T09:08:10","date_gmt":"2025-01-21T09:08:10","guid":{"rendered":"https:\/\/gensetpart.com\/?post_type=product&#038;p=2384"},"modified":"2025-01-21T09:12:53","modified_gmt":"2025-01-21T09:12:53","slug":"sensor-de-aceite-3408607","status":"publish","type":"product","link":"https:\/\/gensetpart.com\/es\/productos\/sensor-de-generador-2\/sensor-de-aceite-3408607","title":{"rendered":"Sensor de presi\u00f3n de aceite Sensor de aceite del generador 3408607"},"content":{"rendered":"<p style=\"text-align: center;\">Sensor de presi\u00f3n de aceite Sensor de aceite del generador 3408607<\/p>\n<p>&nbsp;<\/p>\n<table>\n<tbody>\n<tr class=\"firstRow\">\n<td valign=\"top\" width=\"919\"><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone wp-image-2385\" src=\"https:\/\/gensetpart.com\/wp-content\/uploads\/2025\/01\/H5b6d1432ce2c4f138f4a798a67e87202t.jpg_720x720q50.webp\" alt=\"Sensor de aceite 3408607\" width=\"1200\" height=\"1200\" srcset=\"https:\/\/gensetpart.com\/wp-content\/uploads\/2025\/01\/H5b6d1432ce2c4f138f4a798a67e87202t.jpg_720x720q50.webp 720w, https:\/\/gensetpart.com\/wp-content\/uploads\/2025\/01\/H5b6d1432ce2c4f138f4a798a67e87202t.jpg_720x720q50-300x300.webp 300w, https:\/\/gensetpart.com\/wp-content\/uploads\/2025\/01\/H5b6d1432ce2c4f138f4a798a67e87202t.jpg_720x720q50-80x80.webp 80w, https:\/\/gensetpart.com\/wp-content\/uploads\/2025\/01\/H5b6d1432ce2c4f138f4a798a67e87202t.jpg_720x720q50-600x600.webp 600w, https:\/\/gensetpart.com\/wp-content\/uploads\/2025\/01\/H5b6d1432ce2c4f138f4a798a67e87202t.jpg_720x720q50-100x100.webp 100w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/td>\n<td valign=\"top\" width=\"919\">&nbsp;<\/p>\n<p>Sensor de presi\u00f3n de aceite Sensor de aceite del generador 3408607<\/p>\n<p>&nbsp;<\/p>\n<p>El 3408607 es un equipo de protecci\u00f3n para generadores que se conecta al controlador para proteger el funcionamiento normal del generador. Cuando el generador se encuentra en un nivel anormal, el sensor enviar\u00e1 la se\u00f1al al controlador y luego el controlador enviar\u00e1 una advertencia para asegurarse de encontrar el problema.<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"919\"><img decoding=\"async\" class=\"alignnone wp-image-2386\" src=\"https:\/\/gensetpart.com\/wp-content\/uploads\/2025\/01\/Hd8e35e0d98684490b1ac6c8e05836cceu.jpg_720x720q50.webp\" alt=\"Sensor de aceite 3408607\" width=\"1200\" height=\"1200\" srcset=\"https:\/\/gensetpart.com\/wp-content\/uploads\/2025\/01\/Hd8e35e0d98684490b1ac6c8e05836cceu.jpg_720x720q50.webp 720w, https:\/\/gensetpart.com\/wp-content\/uploads\/2025\/01\/Hd8e35e0d98684490b1ac6c8e05836cceu.jpg_720x720q50-300x300.webp 300w, https:\/\/gensetpart.com\/wp-content\/uploads\/2025\/01\/Hd8e35e0d98684490b1ac6c8e05836cceu.jpg_720x720q50-80x80.webp 80w, https:\/\/gensetpart.com\/wp-content\/uploads\/2025\/01\/Hd8e35e0d98684490b1ac6c8e05836cceu.jpg_720x720q50-600x600.webp 600w, https:\/\/gensetpart.com\/wp-content\/uploads\/2025\/01\/Hd8e35e0d98684490b1ac6c8e05836cceu.jpg_720x720q50-100x100.webp 100w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/td>\n<td valign=\"top\" width=\"919\">&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>Caracter\u00edsticas<\/p>\n<p>&nbsp;<\/p>\n<p><span class=\"magic-8\" data-spm-anchor-id=\"a2700.details.0.i72.7d163ac3lb4vW8\"><span class=\"magic-9\" data-spm-anchor-id=\"a2700.details.0.i71.7d163ac3lb4vW8\"> -Temp:0.8\u00b10.3bar<br \/>\n<\/span><\/span><\/p>\n<p><span class=\"magic-8\" data-spm-anchor-id=\"a2700.details.0.i72.7d163ac3lb4vW8\"><span class=\"magic-9\" data-spm-anchor-id=\"a2700.details.0.i71.7d163ac3lb4vW8\">-Rosca:1\/8-27NPTF<\/span><br \/>\n<\/span><\/p>\n<p>-Peso:70G<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<table class=\"all magic-12\" style=\"height: 297px;\" width=\"1076\">\n<tbody>\n<tr>\n<td colspan=\"7\" rowspan=\"1\">\n<div class=\"magic-13\">\n<div class=\"magic-6\" data-spm-anchor-id=\"a2700.pc-decorate.0.i64.4e1c3333JLWTNx\"><span class=\"magic-9\"><b>Interruptor del sensor de presi\u00f3n de aceite del generador 3408607<\/b><\/span><\/div>\n<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"magic-20\"><span class=\"magic-9\">PRESI\u00d3N(kpa)<\/span><\/div>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"magic-15\"><span class=\"magic-9\">0<\/span><\/div>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"magic-16\"><span class=\"magic-9\">172<\/span><\/div>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"magic-17\"><span class=\"magic-9\">4345<\/span><\/div>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"magic-15\"><span class=\"magic-9\">517<\/span><\/div>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"magic-18\"><span class=\"magic-9\">689<\/span><\/div>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"magic-18\"><span class=\"magic-9\">862<\/span><\/div>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"magic-20\"><span class=\"magic-9\">VALOR DE RESISTENCIA<\/span><\/div>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"magic-15\"><span class=\"magic-9\">226\u00b120<\/span><\/div>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"magic-16\"><span class=\"magic-9\">147\u00b120<\/span><\/div>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"magic-17\"><span class=\"magic-9\">164\u00b120<\/span><\/div>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"magic-15\" data-spm-anchor-id=\"a2700.details.0.i89.73bc24d4n2i6v6\"><span class=\"magic-9\">83\u00b110<\/span><\/div>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"magic-18\"><span class=\"magic-9\">57\u00b110<\/span><\/div>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"magic-18\"><span class=\"magic-9\">34\u00b15<\/span><\/div>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"1\">\n<div class=\"magic-21\"><span class=\"magic-9\" data-spm-anchor-id=\"a2700.details.0.i84.73bc24d4n2i6v6\">Advertencia Temp:0.8\u00b10.3bar<\/span><\/div>\n<\/td>\n<td colspan=\"2\" rowspan=\"1\">\n<div class=\"magic-22\" data-spm-anchor-id=\"a2700.details.0.i86.73bc24d4n2i6v6\"><span class=\"magic-9\" data-spm-anchor-id=\"a2700.details.0.i85.73bc24d4n2i6v6\">Rosca:1\/8-27NPTF<\/span><\/div>\n<\/td>\n<td colspan=\"3\" rowspan=\"1\">\n<div class=\"magic-23\" data-spm-anchor-id=\"a2700.details.0.i87.73bc24d4n2i6v6\"><span class=\"magic-9\" data-spm-anchor-id=\"a2700.details.0.i88.73bc24d4n2i6v6\">Peso:70G<\/span><\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>","protected":false},"excerpt":{"rendered":"<p>Sensor de presi\u00f3n de aceite del generador 3408607,precio de f\u00e1brica con CE verificado.<\/p>","protected":false},"featured_media":2387,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[33,177],"product_tag":[285],"class_list":{"0":"post-2384","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-generator-sensor","7":"product_cat-vod-oil-pressure-sensor","8":"product_tag-oil-sensor-3408607","10":"first","11":"instock","12":"shipping-taxable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/gensetpart.com\/es\/wp-json\/wp\/v2\/product\/2384","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/gensetpart.com\/es\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/gensetpart.com\/es\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/gensetpart.com\/es\/wp-json\/wp\/v2\/comments?post=2384"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/gensetpart.com\/es\/wp-json\/wp\/v2\/media\/2387"}],"wp:attachment":[{"href":"https:\/\/gensetpart.com\/es\/wp-json\/wp\/v2\/media?parent=2384"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/gensetpart.com\/es\/wp-json\/wp\/v2\/product_brand?post=2384"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/gensetpart.com\/es\/wp-json\/wp\/v2\/product_cat?post=2384"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/gensetpart.com\/es\/wp-json\/wp\/v2\/product_tag?post=2384"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}